CC Lynch Welcomes Danny Hutcherson as Newest Water Monitoring Expert

C.C. Lynch & Associates is proud to announce that Danny Hutcherson has joined our team. Danny has served the water and wastewater industry for 40 years. Initially, Danny will serve as our Drinking Water expert; presenting on-line techniques for monitoring water from its source, across process treatment and throughout distribution. His role will add value for…

Read More

6 Reasons You’ll Love Lovibond Turbidimeters

In recent years, many leading turbidimeter vendors have discontinued their models. This change has raised servicing costs and reduced the availability of replacement parts. In September 2017, Lovibond, part of the Tintometer group, released two turbidimeters, the PTV 1000 and the PTV 2000. After researching and testing the products, the C.C. Lynch team was impressed.…

Read More

C.C. LYNCH Adds New EPA Approved Turbidimeters for Surface Water Treatment

We are pleased to announce an addition to our line card. CC Lynch will now carry Lovibond PTV-1000 and PTV-2000 turbidimeters. The PTV Series offers industry-leading accuracy, low water use, easy maintenance and accessible reporting via a smartphone application. A Better Analyzer For decades, EPA Approved Turbidimeters have been dominated by a single manufacturer. So Lovibond…

Read More

An Overview of Teledyne ADCPS Water Resources

Teledyne ADCPS Water Resources can cover a variety of monitoring needs from streams and rivers to reservoirs and irrigation channels. Their monitoring devices include both fixed-mount and boat-mount configurations, capable of monitoring water velocity, stage and discharge data at depths of .12 meters to 300 meters. Teledyne offers seven different products with varying specialties: the…

Read More

Examining the In-Situ Aqua TROLL® 600 Multiparamter Sonde

The In-Situ Aqua TROLL® 600 Multiparameter Sonde is a versatile device with a lengthy battery life capable of testing in fresh water or salt water and for long-term or short-term deployments. The Aqua TROLL® 600 connects via Bluetooth with the VuSitu™ Mobile Smartphone App and includes an LCD display for checking overall probe functionality. This…

Read More

The best magmeter for potable water applications

ElectroMagnetic Flowmeters, or magmeters, have long earned their reputation for metering flow of water and wastewater in closed-pipe applications.  When properly applied, the accuracy can be within fractions of 1 percent.  Magmeters are calibrated on a laboratory flow stand and hold NIST Traceable Calibration Certificates. For potable water metering, magmeters offer no moving parts, filters…

Read More

Open channel flow measurement techniques

NO FLUME, NO WEIR, NO PROBLEM Arguably, the most important measurement taken in and around water/wastewater systems is flow. In open channel applications, the most common flow measurement technique is through Primary/Secondary devices. Primary devices include flumes and weirs that create a reliable relationship between water level and flow rate; in the form of a…

Read More

How Thermal Energy Meters Reduce Costs at University Campuses

The cooling and heating of a university campus is one of the primary areas where better energy management, including improved efficiency and energy reduction, brings some of the highest returns. Every university to some extent is now engaged in this process, and one of the first things that has to be addressed is the metering…

Read More

Top FAQs on Third Party Flow Meter Calibration

What is third party flow meter calibration? Third party flow meter calibration is when a recognized independent service company tests and adjusts your flow meter(s) for optimum performance, following the manufacturer’s recommended procedure. Why do I need third party flow meter calibration? There are several reasons third party calibration is recommended, including: Most permits require…

Read More

3 Reasons to Rent Water Monitoring Equipment from the Manufacturer

Editor’s note: This article originally appeared on the In-Situ blog in May 2015. There are several reasons you might consider renting environmental sampling equipment: maybe it just makes more sense to rent equipment for a project rather than buy it, or perhaps you want to try the product before you make the commitment. Whatever the…

Read More

Case Study:Texas Municipality Diverts Flow in Large Diameter Sewer Lines

By: Brandon Dalton Customer In the past few years, there have been several sewer line rehabilitation projects in Texas involving large diameter sewers (6 feet to 11 feet diameter) located 50 feet to 60 feet below ground. These projects have either required the city to block flows in order to divert to other sewer lines…

Read More

6 Benefits of Clamp-On Ultrasonic Flow Meters

According to the American Water Works Association, public water systems lose approximately $2.8 billion in annual revenue from water loss. Non-Revenue Water (NRW), combined with the environmental impact, has drinking water specialists looking for more flexible and accurate flow measurement technologies to locate, and  quantify, sources of loss. The Transit Time Ultrasonic technique provides a…

Read More

WEFTEC New Orleans 2016

Are you attending WEFTEC New Orleans this year?  Be sure to visit some of the Manufacturers represented by CC Lynch and Associates.  Booth numbers include 2557, 1647, 1501, 3807 and 3063. S::can Measuring Systems is exhibiting in Booth 2557 at WEFTEC 2016, the Water Environment Federation Annual Technical Exhibition and Conference, and we hope to see you there! Be…

Read More

Welcome FLEXIM to Our Product Line

We at CC Lynch and Associates are excited about our newest flow meter for drinking water, wastewater and thermal energy monitoring; by FLEXIM. FLEXIM offers portable and permanent metering solutions with external pipe “clamp-on” technology and ultrasonic sound. Advantages of FLEXIM ultrasonic clamp-on meters include: Quick and Easy Installation without process interruption or flow by-pass Low installation…

Read More

Solar Power for Flow Monitoring without AC. No Power No Problem.

Solar power arrangements for flow monitoring systems can be an effective remedy for remote locations where power is often unavailable, or too time consuming / expensive to run. Several models of flow meters, auto samplers and water quality analyzers come in models that can operate on 12 or 24 VDC. A solar power system mainly…

Read More

KROHNE Level Radar and TDR Promotional Offer

To celebrate Krohne’s new manufacturing capability at their Peabody, Massachusetts facility we are pleased to announce a price promotion for the newest KROHNE level devices produced there. These products can now be produced and shipped within 5 days of order receipt.

Read More

Measuring Flow in Gravity Sewers

There is nothing more difficult than measuring flow in gravity sewers. WRUA bought 34 Isco Area Velocity Meters – Quality Equipment & Post-Sales Service Sealed the Deal.  By Mary Therese Gookin West Rankin Utility Authority (WRUA) provides wastewater treatment for seven neighboring members serving a population of 100,000.  Bruce Stephens, Executive Director of WRUA, a…

Read More

Optimizing Your Treatment Process with Microscopic Particulate Analysis

Are you optimizing your treatment processes by using data from a microscope?  Are you monitoring your drinking water source water for algae blooms that could cause taste and odor issues?  Or, is your team short-staffed and overwhelmed with other responsibilities that result in the microscope in your lab collecting dust and your team to have…

Read More

Temporary Flow Measurement Solution With An Improperly Installed Flume

Recently one of our customers was contracted to perform a temporary flow study at a commercial bakery.  The purpose of the flow study was to quantify the volume of process wastewater being discharged so a pretreatment system could be designed and installed to satisfy the requirements of the local water control district.  Our customer reached…

Read More

Multiple Outfall Flow Monitoring Application Challenge

A recent application challenge was presented to us by an industrial customer in the Southeast Texas area. The customer was relocating their final outfall from their wetland treatment system to a remote area without AC power. They needed a way to measure flow rates in three side by side 36” culverts and collect flow weighted…